Note
Access to this page requires authorization. You can try signing in or changing directories.
Access to this page requires authorization. You can try changing directories.
This IOCTL retrieves the authentication status of the connection.
Parameters
hDeviceContext
[in] Device context handle.fSelector
[in] Equals BTH_HCI_IOCTL_HANDLE_AUTHENTICATED.cInBuffer
[in] Equals 2.pInBuffer
Must be an aligned pointer to an unsigned short handle.cOutBuffer
[in] Equals 4.pOutBuffer
[in] Must point to an aligned unsigned integer.[out] Contains TRUE if the connection is authenticated.
pcDataReturned
[out] Equals cOutBuffer.
Return Values
If the call succeeds, the return value is ERROR_SUCCESS.
If the function fails, the following table shows a list of possible error values.
Error value | Description |
---|---|
ERROR_CONNECTION_INVALID | The connection handle was not found. |
ERROR_INVALID_PARAMETER | Parameters are invalid (buffers are not properly sized). |
ERROR_SERVICE_NOT_ACTIVE | HCI is not active or there is no hardware. |
Requirements
OS Versions: Windows CE .NET 4.0 and later.
Header: Bt_ddi.h.
Send Feedback on this topic to the authors