Represents a synchronization provider that communicates with a SQL Server database and shields other Sync Framework components from the specific implementation of the database.
The following tables list the members exposed by the SqlSyncProvider type.
Public Constructors
Name | Description | |
---|---|---|
![]() |
SqlSyncProvider | Overloaded. Initializes a new instance of the SqlSyncProvider class. |
Top
Public Properties
Name | Description | |
---|---|---|
![]() |
BatchingDirectory | Gets or sets the directory in which batch files are spooled to disk. This property is not CLS-compliant. (Inherited from RelationalSyncProvider.) |
![]() |
CleanupBatchingDirectory | Gets or sets whether to clean up batching files after the changes in the files have been applied to the destination. This property is not CLS-compliant. (Inherited from RelationalSyncProvider.) |
![]() |
Configuration | Not implemented by RelationalSyncProvider. An exception of type NotSupportedException is thrown if you attempt to access this property. This property is not CLS-compliant. (Inherited from RelationalSyncProvider.) |
![]() |
Connection | Gets or sets an IDbConnection object that is used to connect to the database. This property is not CLS-compliant. (Inherited from RelationalSyncProvider.) |
![]() |
DestinationCallbacks | Gets an object that a synchronization application can use to register to receive notification of events that occur during synchronization. This property is not CLS-compliant. (Inherited from KnowledgeSyncProvider.) |
![]() |
IdFormats | Gets a SyncIdFormatGroup object that is used to identify entities in a synchronization session. This property is not CLS-compliant. (Inherited from RelationalSyncProvider.) |
![]() |
MemoryDataCacheSize | Gets or sets the maximum amount of memory (in KB) that Sync Framework uses to cache changes before spooling those changes to disk. This property is not CLS-compliant. (Inherited from RelationalSyncProvider.) |
![]() |
ObjectPrefix | Gets or sets the optional prefix that is used to identify objects that Sync Framework creates. This property is not CLS-compliant. |
![]() |
ObjectSchema | Gets or sets the optional database schema in which Sync Framework creates objects. This property is not CLS-compliant. |
![]() |
ScopeName | Overridden. Sets the name of the scope to synchronize, which is a logical group of tables with optional filters. This property is not CLS-compliant. |
![]() |
SyncProviderPosition | Gets or sets a SyncProviderPosition enumeration value that represents whether a provider is associated with the local or remote database. This property is not CLS-compliant. (Inherited from RelationalSyncProvider.) |
Top
Public Methods
(see also Protected Methods )
Name | Description | |
---|---|---|
![]() |
BeginSession | Overridden. Called by the SyncOrchestrator to indicate that a synchronization session has started. This method is not CLS-compliant. |
![]() |
Dispose | Overloaded. Releases the resources that are used by the RelationalSyncProvider.(Inherited from RelationalSyncProvider.) |
![]() |
EndSession | (Inherited from RelationalSyncProvider.) |
![]() |
Equals | Overloaded. (Inherited from Object.) |
![]() |
GetChangeBatch | (Inherited from RelationalSyncProvider.) |
![]() |
GetFullEnumerationChangeBatch | (Inherited from RelationalSyncProvider.) |
![]() |
GetHashCode | (Inherited from Object.) |
![]() |
GetSyncBatchParameters | (Inherited from RelationalSyncProvider.) |
![]() |
GetType | (Inherited from Object.) |
![]() |
ProcessChangeBatch | (Inherited from RelationalSyncProvider.) |
![]() |
ProcessFullEnumerationChangeBatch | (Inherited from RelationalSyncProvider.) |
![]() ![]() |
ReferenceEquals | (Inherited from Object.) |
![]() |
ToString | (Inherited from Object.) |
Top
Protected Methods
Name | Description | |
---|---|---|
![]() |
CreateApplicationTransaction | When overridden in a derived class, enables an explicit transaction to be created in which to apply changes to an Oracle database. This method is not CLS-compliant. (Inherited from RelationalSyncProvider.) |
![]() |
CreateEnumerationTransaction | When overridden in a derived class, enables an explicit transaction to be created in which to enumerate changes from an Oracle database. This method is not CLS-compliant. (Inherited from RelationalSyncProvider.) |
![]() |
Dispose | Overloaded. (Inherited from RelationalSyncProvider.) |
![]() |
Finalize | (Inherited from Object.) |
![]() |
MemberwiseClone | (Inherited from Object.) |
![]() |
OnApplyChangeFailed | (Inherited from RelationalSyncProvider.) |
![]() |
OnApplyingChanges | (Inherited from RelationalSyncProvider.) |
![]() |
OnApplyMetadataFailed | (Inherited from RelationalSyncProvider.) |
![]() |
OnChangesApplied | (Inherited from RelationalSyncProvider.) |
![]() |
OnChangesSelected | (Inherited from RelationalSyncProvider.) |
![]() |
OnPeerOutdated | (Inherited from RelationalSyncProvider.) |
![]() |
OnSelectingChanges | (Inherited from RelationalSyncProvider.) |
![]() |
OnSyncProgress | (Inherited from RelationalSyncProvider.) |
Top
Public Events
Name | Description | |
---|---|---|
![]() |
ApplyChangeFailed | Occurs during uploading, after failing to apply a row at a node. This event is not CLS-compliant. (Inherited from RelationalSyncProvider.) |
![]() |
ApplyingChanges | Occurs during uploading, after connecting to the database but before applying changes. This event is not CLS-compliant. (Inherited from RelationalSyncProvider.) |
![]() |
ApplyMetadataFailed | Occurs during uploading, after failing to apply metadata for a row. This event is not CLS-compliant. (Inherited from RelationalSyncProvider.) |
![]() |
BatchApplied | Occurs after each batch of changes has been applied to the destination. This event is not CLS-compliant. (Inherited from RelationalSyncProvider.) |
![]() |
BatchSpooled | Occurs after each batch of changes has been written to disk. This event is not CLS-compliant. (Inherited from RelationalSyncProvider.) |
![]() |
ChangesApplied | Occurs during uploading, after applying changes but before disconnecting from the database. This event is not CLS-compliant. (Inherited from RelationalSyncProvider.) |
![]() |
ChangesSelected | Occurs during downloading, after enumerating changes but before disconnecting from the database. This event is not CLS-compliant. (Inherited from RelationalSyncProvider.) |
![]() |
SelectingChanges | Occurs during downloading, after connecting to the database but before selecting changes. This event is not CLS-compliant. (Inherited from RelationalSyncProvider.) |
![]() |
SyncPeerOutdated | Occurs before enumeration of changes if the destination node is outdated. This event is not CLS-compliant. (Inherited from RelationalSyncProvider.) |
![]() |
SyncProgress | Occurs during the selection of changes (per table) and the application of changes (per row). This event is not CLS-compliant. (Inherited from RelationalSyncProvider.) |
Top
See Also
Reference
SqlSyncProvider Class
Microsoft.Synchronization.Data.SqlServer Namespace