You can design ABO applications so that they are notified when certain events occur. To receive event notifications, a listener object must implement a COM sink of a class inherited from the IMSAdminBaseSink interface. Also, the listener object should be free-threaded because notifications are asynchronous and might arrive out of order.
Example Code
The following code example shows you how to use the C++ programming language to to implement the IMSAdminBaseSink interface in a listener object. This example requires the header files iadmw.h and iiscnfg.h.
class CSvcExtImpIMDCOMSINK : public IMSAdminBaseSink {
public:
CSvcExtImpIMDCOMSINK();
~CSvcExtImpIMDCOMSINK();
STDMETHODIMP
QueryInterface(REFIID riid, void **ppObject);
STDMETHODIMP_(ULONG)
AddRef();
STDMETHODIMP_(ULONG)
Release();
STDMETHODIMP
SinkNotify(
DWORD dwMDNumElements,
MD_CHANGE_OBJECT pcoChangeList[ ]);
STDMETHODIMP
ShutdownNotify();
private:
ULONG m_dwRefCount;
};
CSvcExtImpIMDCOMSINK::CSvcExtImpIMDCOMSINK():
m_dwRefCount(1),
{
}
CSvcExtImpIMDCOMSINK::~CSvcExtImpIMDCOMSINK()
{
}
STDMETHODIMP
CSvcExtImpIMDCOMSINK::QueryInterface(
REFIID riid,
void **ppObject)
{
if ( ppObject == NULL )
{
return E_INVALIDARG;
}
*ppObject = NULL;
if (riid==IID_IUnknown || riid==IID_IMSAdminBaseSink)
{
*ppObject = (IMSAdminBaseSink *) this;
}
else
{
return E_NOINTERFACE;
}
AddRef();
return NO_ERROR;
}
STDMETHODIMP_(ULONG)
CSvcExtImpIMDCOMSINK::AddRef()
{
DWORD dwRefCount;
dwRefCount = InterlockedIncrement((long *)&m_dwRefCount);
return dwRefCount;
}
STDMETHODIMP_(ULONG)
CSvcExtImpIMDCOMSINK::Release()
{
DWORD dwRefCount;
dwRefCount = InterlockedDecrement((long *)&m_dwRefCount);
if (dwRefCount == 0)
{
delete this;
}
return dwRefCount;
}
STDMETHODIMP
CSvcExtImpIMDCOMSINK::SinkNotify(
DWORD dwMDNumElements,
MD_CHANGE_OBJECT __RPC_FAR pcoChangeList[ ]) {
DWORD i;
DWORD j;
for (i = 0; i < dwMDNumElements; i++)
{
if ( ( pcoChangeList[i].dwMDChangeType & MD_CHANGE_TYPE_SET_DATA ) != 0)
{
for (j = 0; j < pcoChangeList[i].dwMDNumDataIDs; j++)
{
switch (pcoChangeList[i].pdwMDDataIDs[j])
{
case MD_*:
// Do something
break;
default:
break;
//
// No specific action for this command
//
}
}
}
}
return S_OK;
}
STDMETHODIMP
CSvcExtImpIMDCOMSINK::ShutdownNotify()
{
return S_OK;
}