Syntax
class MsSna_ServicePrint : MsSna_Service
{
String Name;
boolean NoEventLogOnSkippingTransparentSection;
boolean UseProportionalFontChange;
boolean FlushFinalFF;
boolean DelayPrintStart;
boolean AlwaysDoNL;
boolean NoSpaceAfterFF;
boolean DoAllFF;
boolean IgnoreCharsUnder3F;
boolean UseFixedTabs;
sint32 ActivationRetryInterval;
sint32 ActivationRetryLimit;
String StatusText;
};
Properties
Name
Data Type: StringQualifiers: Key, MAXLEN(16)Access Type: Read/Write
The Host Print service name. Name is the same as the machine name.
NoEventLogOnSkippingTransparentSection
Data Type: BooleanAccess Type: Read/Write
true to prevent an entry in the Event Log every time a print service skips a transparent section found while printing a host print job; otherwise, false.
UseProportionalFontChange
Data Type: BooleanAccess Type: Read/Write
true to prevent overlapping characters in documents containing nonfixed type fonts printed through Host Print service; otherwise, false.
FlushFinalFF
Data Type: BooleanAccess Type: Read/Write
true to cause Host Print service to explicitly form-feed the document at the end of a print job; otherwise, false.
DelayPrintStart
Data Type: BooleanAccess Type: Read/Write
true to delay the start of the print job until printable data is received by Host Print services; otherwise, false.
AlwaysDoNL
Data Type: BooleanAccess Type: Read/Write
true to insert a new line when the Host Print service determines that the Maximum Print Position has been reached for a particular line of data; otherwise, false.
NoSpaceAfterFF
Data Type: BooleanAccess Type: Read/Write
true to prevent print services from inserting a space character following a form feed; otherwise, false.
DoAllFF
Data Type: BooleanAccess Type: Read/Write
true to force the printer driver to honor all form-feed commands; otherwise, false.
IgnoreCharsUnder3F
Data Type: BooleanAccess Type: Read/Write
true to cause the Host Print service to ignore hexadecimal characters 3F and below; otherwise, false.
UseFixedTabs
Data Type: BooleanAccess Type: Read/Write
true to disable normal tab functionality (such as aligning tabs in columns) and interpret each tab as a fixed number of spaces; otherwise, false.
ActivationRetryInterval
Data Type: sint32Access Type: Read/Write
The number of seconds to wait before trying to print the job again. The default value is 10 seconds.
ActivationRetryLimit
Data Type: sint32Access Type: Read/Write
The number of times Host Print service attempts to activate the APPC conversation following a terminated connection. The default value is -1 (infinite).
StatusText
Data Type: StringAccess Type: Read/Write
The current status of Host Print service. The following table describes the possible values for StatusText.
Value | Description |
---|---|
Not configured | The service is not configured. |
Inactive | The service is inactive. |
Pending | The service is pending. |
Stopping | The service is stopping. |
Active | The service is active. |
Out of Date | The service is out-of-date. |
Paused | The service is paused. |
Methods
Method | Description |
---|---|
Start | Starts the service. |
Stop | Stops the service. |
Requirements